| Peer-Reviewed

Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption

Received: 30 November 2014     Accepted: 5 December 2014     Published: 16 December 2014
Views:       Downloads:
Abstract

Mass energy absorption coefficients and effective atomic numbers for photon energy absorption, ZPEAeff have been calculated in the energy range from 1 keV to 20 MeV for human tissues, Adipose Tissue, Blood Whole, Bone Cortical, Brain Grey/White Matter, Breast Tissue, Eye Lens, Lung Tissue, Muscle Skeletal, Ovary, Testis, Soft Tissue. Mass energy absorption coefficients and effective atomic numbers for photon energy absorption have also been calculated for commonly used thermoluminescent dosimeters,TLD, in the energy range from 1 keV to 20 MeV. The energy dependence of the mass energy absorption of human tissues and TL dosimeters are shown graphically. The tissue equivalency of TLDs is investigated. The effects of the elemental composition on effective atomic numbers for photon energy absorption and the tissue equivalency of TLDs are discussed.

Published in American Journal of Physics and Applications (Volume 2, Issue 6)
DOI 10.11648/j.ajpa.20140206.15
Page(s) 145-149
Creative Commons

This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited.

Copyright

Copyright © The Author(s), 2014. Published by Science Publishing Group

Keywords

Effective Atomic Number, Human Tsissue, Thermoluminescent Dosimeters, Photon Energy Absorption

References
[1] J. H. Hubbell, “Photon mass attenuation and energy absorption coefficients from 1 keV to 20 MeV” Int. J. Appl. Radiat. Isot. Vol. 33, pp. 1269–1290, 1982.
[2] J. H. Hubbell and S. M. Seltzer, “Tables of x-ray mass attenuation coefficients and mass energy absorption coefficients 1 keV to 20 MeV for elements Z=1 to 92 and 48 additional substances of dosimetric interest” NISTIR–5632, 1995.
[3] Shivaramu and V. Ramprasath, “Effective atomic numbers for photon energy absorption and energy dependence of some thermoluminescent dosimetric compounds” Nucl. Instrum. Methods Phys. Res. B vol. 168, pp. 294-304, 2000.
[4] I. Han and L. Demir, “Mass attenuation coefficients, effective atomic and electron numbers of Ti and Ni alloys” Radiat. Meas. Vol. 44, pp. 289, 2009.
[5] V. R. K. Murty, D. P. Winkoun and K. R. S. Devan, “Effective atomic numbers for W/Cu alloy using transmission experiments” Appl. Radiat. Isot. Vol. 53, pp.945-948, 2000.
[6] S. R. Manohara and S. M. Hanagodimath, “Studies on effective atomic numbers and electron densities of essential amino acids in the energy range 1 keV–100 GeV” Nucl. Instrum. Methods Phys. Res. B vol. 258, pp. 321, 2007.
[7] M. Rao, “Interaction of low energy photons with biological materials and effective atomic numbers” Med. Phys. vol. 12, pp. 745–748, 1985.
[8] S. R. Manohara, S. M. Hanagodimath, K. S. Thind, L. Gerward, “The effective atomic number revisited in the light of modern photon-interaction cross-section databases” Appl. Radiat. Isot. vol. 68, pp. 784–787, 2010.
[9] A. Un and Y. Sahin, “Determination of mass attenuation coefficients, effective atomic and electron numbers, mean free paths and kermas for PbO, barite and some boron ores” Nucl. Instrum. Methods Phys. Res. B vol. 269, pp. 1506, 2011.
[10] A. Un and Y. Sahin, “Determination of mass attenuation coefficients, effective atomic numbers, effective electron numbers and kermas for Earth and Martian soils” Nucl. Instrum. Methods Phys. Res. B vol. 288, pp. 42-47, 2012.
[11] Shivaramua, R. Vijayakumar, L. Rajasekaranb and N. Ramamurthyb, “Effective atomic numbers for photon energy absorption of some low-Z substances of dosimetric interest” Radiat. Phys. Chem. Vol. 62, pp. 371–377, 2001.
[12] Shivaramu, “Effective atomic numbers for photon energy absorption and photon attenuation of tissues from human organs” Med. Dosim. Vol.27, pp. 1–9, 2002.
[13] T. K. Kumar and K.V. Reddy, “Effective atomic numbers for materials of dosimetric interest” Radiat. Phys. Chem. Vol. 50, pp. 545 553, 1997.
[14] S. R. Manohara and S. M. Hanagodimath, “Effective atomic numbers for photon energy absorption of essential amino acids in the energy range 1 keV–20 MeV” Nucl. Instrum. Methods, B vol. 264, pp. 9, 2007.
[15] ICRU, Report No 44 “Tissue substitutes in radiation dosimetry and measurement” (International Commission of Radiation Units and Measurements, Bethesda, MD), 1989.
[16] P. N. Mobit, A. E. Nahum and P. Maylesz, “Monte Carlo study of the quality dependence factors of common TLD materials in photon and electron beams” Phys. Med. Biol. Vol. 43, pp.2015–2032, 1998.
[17] C. Furetta, Handbook of Thermoluminescence, World Scientific Publishing co.Pte. Ltd., Singapure, 2003.
[18] M. Danilkin, A. Lust, M. Kerikmäe, V. Seeman, H. Mändar and M. Must, “CaF2:Mn extreme dosimeter: Effects of Mn concentration on thermoluminescence mechanisms and properties” Radiat. Measur. Vol. 41, pp. 677 – 681, 2006.
[19] Y. R. Devi and S. D. Singh, “Synthesis and TL glow curve analysis of BaSO :Eu,Dy phosphor” J. Lumin. Vol. 132, pp. 1575–1580, 2012.
[20] P. R. Gonzalez, C. Furetta, B. E. Calvo, M. I. Gaso and E. Cruz-Zaragoza, “Dosimetric characterization of a new preparation of BaSO4 activated by Eu ions” Nucl. Instrum. Methods, B vol. 260, pp. 685–692, 2007.
[21] S. S. Shinde, T. K. Gundu Rao, S.S. Sanaye and B.C. Bhatt, “Tl and esr characteristics of baso4:eu co-doped with na/p: influence of method of preparation” Radiat. Prot. Dosim. Vol. 84, pp. 215–218, 1999.
[22] K. Shinsho, Watanabe, E. and Urushiyama, A., Elucidation of the annealing process required in the preparation of the thermoluminescence phosphor of CaSO4 :Tm, J. Appl. Phys. vol. 100, pp. 093514, 2006.
[23] J. H. Hubbell, “Review of photon interaction cross section data in medical and biological context” Phys. Med. Biol. Vol. 44, pp. R1–R22, 1999.
Cite This Article
  • APA Style

    Adem Un, Mümine Un, Ibrahim Han. (2014). Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption. American Journal of Physics and Applications, 2(6), 145-149. https://doi.org/10.11648/j.ajpa.20140206.15

    Copy | Download

    ACS Style

    Adem Un; Mümine Un; Ibrahim Han. Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption. Am. J. Phys. Appl. 2014, 2(6), 145-149. doi: 10.11648/j.ajpa.20140206.15

    Copy | Download

    AMA Style

    Adem Un, Mümine Un, Ibrahim Han. Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption. Am J Phys Appl. 2014;2(6):145-149. doi: 10.11648/j.ajpa.20140206.15

    Copy | Download

  • @article{10.11648/j.ajpa.20140206.15,
      author = {Adem Un and Mümine Un and Ibrahim Han},
      title = {Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption},
      journal = {American Journal of Physics and Applications},
      volume = {2},
      number = {6},
      pages = {145-149},
      doi = {10.11648/j.ajpa.20140206.15},
      url = {https://doi.org/10.11648/j.ajpa.20140206.15},
      eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ajpa.20140206.15},
      abstract = {Mass energy absorption coefficients and effective atomic numbers for photon energy absorption, ZPEAeff have been calculated in the energy range from 1 keV to 20 MeV for human tissues, Adipose Tissue, Blood Whole, Bone Cortical, Brain Grey/White Matter, Breast Tissue, Eye Lens, Lung Tissue, Muscle Skeletal, Ovary, Testis, Soft Tissue. Mass energy absorption coefficients and effective atomic numbers for photon energy absorption have also been calculated for commonly used thermoluminescent dosimeters,TLD, in the energy range from 1 keV to 20 MeV. The energy dependence of the mass energy absorption of human tissues and TL dosimeters are shown graphically. The tissue equivalency of TLDs is investigated. The effects of the elemental composition on effective atomic numbers for photon energy absorption and the tissue equivalency of TLDs are discussed.},
     year = {2014}
    }
    

    Copy | Download

  • TY  - JOUR
    T1  - Comparison of Some Human Tissues and Some Commonly Used Thermoluminescent Dosimeters for Photon Energy Absorption
    AU  - Adem Un
    AU  - Mümine Un
    AU  - Ibrahim Han
    Y1  - 2014/12/16
    PY  - 2014
    N1  - https://doi.org/10.11648/j.ajpa.20140206.15
    DO  - 10.11648/j.ajpa.20140206.15
    T2  - American Journal of Physics and Applications
    JF  - American Journal of Physics and Applications
    JO  - American Journal of Physics and Applications
    SP  - 145
    EP  - 149
    PB  - Science Publishing Group
    SN  - 2330-4308
    UR  - https://doi.org/10.11648/j.ajpa.20140206.15
    AB  - Mass energy absorption coefficients and effective atomic numbers for photon energy absorption, ZPEAeff have been calculated in the energy range from 1 keV to 20 MeV for human tissues, Adipose Tissue, Blood Whole, Bone Cortical, Brain Grey/White Matter, Breast Tissue, Eye Lens, Lung Tissue, Muscle Skeletal, Ovary, Testis, Soft Tissue. Mass energy absorption coefficients and effective atomic numbers for photon energy absorption have also been calculated for commonly used thermoluminescent dosimeters,TLD, in the energy range from 1 keV to 20 MeV. The energy dependence of the mass energy absorption of human tissues and TL dosimeters are shown graphically. The tissue equivalency of TLDs is investigated. The effects of the elemental composition on effective atomic numbers for photon energy absorption and the tissue equivalency of TLDs are discussed.
    VL  - 2
    IS  - 6
    ER  - 

    Copy | Download

Author Information
  • Department of Physics, Faculty of Arts and Sciences, University of A?r? Ibrahim ?e?en, 04100 A?r?, Turkey

  • Institute of Science, University of A?r? Ibrahim ?e?en, 04100 A?r?, Turkey

  • Department of Physics, Faculty of Arts and Sciences, University of A?r? Ibrahim ?e?en, 04100 A?r?, Turkey

  • Sections