This paper presented the results of a solar air collector with internal crimped fins. It consists of a flat plate collectors with seven internal crimped fins and has the total collection surface area of 2m2. The investigation results indicate that the introduction of internal crimped fins can strengthen the convective heat transfer process and lessen the radiation heat loss, which contributes to efficiency improvement. In case the optimum number of for this study was seven crimped fins, The result of the air mass flow rate should be controlled in a range of 0.025–0.027kg/s. The influence of internal crimped fins number, ratio between leght wing and fin pitch, as well as the air mass flow rate on the collector performance presented in this paper. The operating parameters such as the surrounding temperature, solar radiation intensity have significant influence on the temperature rise but have little influence on collector efficiency, which indicates that this kind of solar air collector could be applied in a wide range of geographical latitude.
Published in | International Journal of Energy and Power Engineering (Volume 7, Issue 2) |
DOI | 10.11648/j.ijepe.20180702.11 |
Page(s) | 19-26 |
Creative Commons |
This is an Open Access article, distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution and reproduction in any medium or format, provided the original work is properly cited. |
Copyright |
Copyright © The Author(s), 2018. Published by Science Publishing Group |
Air Collectors, Baffles, Collector Efficiency, Flat Plate Collector, Solar Air Heater, Solar Radiation
[1] | S. V. Karmare, A. N. Tikekar, “Analysis of fluid flow and heat transfer in a rib grit roughened surface solar air heater using CFD”, Solar Energy, 84, 2010, pp. 409–417. |
[2] | M. S. Manjunath, K. Vasudeva Karanth, N. Yagnesh Sharma “Numerical Analysis of the Influence of Spherical Turbulence Generators on Heat Transfer Enhancement of Flat Plate Solar Air Heater”, Solar Energy, 131, 2016, pp. 47-60. |
[3] | A. Hachei, “Thermal performance enhancement of solar air heaters, by a fan blown absorber plate with retangular fins ”, In ternational journal of energy research, 19, 1995, pp. 567-578. |
[4] | A. M. El-Sawi, A. S. Wifi, M. Y. Younan, E. A. Elsayed, B. B. Basily, “Application of folded sheet metal in flat bed solar air collectors”, Applied Thermal Engineering, 30 2010, pp. 864–871. |
[5] | B. M. Ramani, A. Gupta, R. Kumar, “Performance of a double pass solar air collector”, Solar Energy, 84, 2010, pp1929–1937. |
[6] | Tao Liu, Wenxian Lin, Wenfeng Gao, “A Parametric Study on the Thermal Performance of a Solar Air Collector with a V-Groove Absorber” International Journal of Green Energy, 2007, pp. 601-622. |
[7] | Wenfeng Gao, Wenxian Lin, Tao Liu, Chaofeng Xia, “Analytical and experimental studies on the thermal performance of cross-corrugated and flat-platesolarairheaters”, Applied Energy, 84, 2007, pp. 425–441. |
[8] | X. Q. Zhai, Y. J. Dai, R. Z. Wang, “Experimental investigation on air heating and natural ventilation of a solar air collector”, Energy and Building, 37, 2005 pp. 373–381. |
[9] | A. A. Razak, Z. A. A. Majid, W. H. Azmi, M. H. Ruslan, Sh. Choobchian, G. Najafi,“Review onmatrix thermal absorber designs for solar air collector” Renewable and Sustainable EnergyReviews, 64, 2016, pp. 682–693. |
[10] | Ben Slama Romdhane, “The air solar collectors: Comparative study, introduction of bafflesto favor the heat transfer”, Solar Energy, 64, 2007, pp. 139–149. |
[11] | Jianjun Hu, Xishan Sun, Jinliang Xu, “Numerical analysis of mechanical ventilation solar air collector with internal baffles”, Solar Energy, 62, 2013, pp. 230-238. |
APA Style
Nguyen Xuan Lam, Le Minh Nhut. (2018). Experimental Study on Solar Air Collector with Internal Crimped Fins. International Journal of Energy and Power Engineering, 7(2), 19-26. https://doi.org/10.11648/j.ijepe.20180702.11
ACS Style
Nguyen Xuan Lam; Le Minh Nhut. Experimental Study on Solar Air Collector with Internal Crimped Fins. Int. J. Energy Power Eng. 2018, 7(2), 19-26. doi: 10.11648/j.ijepe.20180702.11
AMA Style
Nguyen Xuan Lam, Le Minh Nhut. Experimental Study on Solar Air Collector with Internal Crimped Fins. Int J Energy Power Eng. 2018;7(2):19-26. doi: 10.11648/j.ijepe.20180702.11
@article{10.11648/j.ijepe.20180702.11, author = {Nguyen Xuan Lam and Le Minh Nhut}, title = {Experimental Study on Solar Air Collector with Internal Crimped Fins}, journal = {International Journal of Energy and Power Engineering}, volume = {7}, number = {2}, pages = {19-26}, doi = {10.11648/j.ijepe.20180702.11}, url = {https://doi.org/10.11648/j.ijepe.20180702.11}, eprint = {https://article.sciencepublishinggroup.com/pdf/10.11648.j.ijepe.20180702.11}, abstract = {This paper presented the results of a solar air collector with internal crimped fins. It consists of a flat plate collectors with seven internal crimped fins and has the total collection surface area of 2m2. The investigation results indicate that the introduction of internal crimped fins can strengthen the convective heat transfer process and lessen the radiation heat loss, which contributes to efficiency improvement. In case the optimum number of for this study was seven crimped fins, The result of the air mass flow rate should be controlled in a range of 0.025–0.027kg/s. The influence of internal crimped fins number, ratio between leght wing and fin pitch, as well as the air mass flow rate on the collector performance presented in this paper. The operating parameters such as the surrounding temperature, solar radiation intensity have significant influence on the temperature rise but have little influence on collector efficiency, which indicates that this kind of solar air collector could be applied in a wide range of geographical latitude.}, year = {2018} }
TY - JOUR T1 - Experimental Study on Solar Air Collector with Internal Crimped Fins AU - Nguyen Xuan Lam AU - Le Minh Nhut Y1 - 2018/05/25 PY - 2018 N1 - https://doi.org/10.11648/j.ijepe.20180702.11 DO - 10.11648/j.ijepe.20180702.11 T2 - International Journal of Energy and Power Engineering JF - International Journal of Energy and Power Engineering JO - International Journal of Energy and Power Engineering SP - 19 EP - 26 PB - Science Publishing Group SN - 2326-960X UR - https://doi.org/10.11648/j.ijepe.20180702.11 AB - This paper presented the results of a solar air collector with internal crimped fins. It consists of a flat plate collectors with seven internal crimped fins and has the total collection surface area of 2m2. The investigation results indicate that the introduction of internal crimped fins can strengthen the convective heat transfer process and lessen the radiation heat loss, which contributes to efficiency improvement. In case the optimum number of for this study was seven crimped fins, The result of the air mass flow rate should be controlled in a range of 0.025–0.027kg/s. The influence of internal crimped fins number, ratio between leght wing and fin pitch, as well as the air mass flow rate on the collector performance presented in this paper. The operating parameters such as the surrounding temperature, solar radiation intensity have significant influence on the temperature rise but have little influence on collector efficiency, which indicates that this kind of solar air collector could be applied in a wide range of geographical latitude. VL - 7 IS - 2 ER -